Sunday, March 25, 2012

Info about lra.

BTU - British Thermal Unit.
LRA - Lock Rotor Ampere
FLA - Full Load Ampere

1 ton - 12,000 btu

24,000 btu - 12.3 ampere - 2 ton - 2.5 horsepower

18,000 btu - 8.7 ampere - 1.5 ton - 2 horsepower

Capacity
Kcal 6,800 - BTU 27,000 - TUBE SIZE - High side - 3/8 Low side - 5/8

Kcal 9,200 - btu 36,000 - 3 ton - high side - 3/8 low side - 3/4

Kcal 11,600 - btu 46,000 - high - 1/2 low - 3/4


LRA -87 = RLA - 18.2 = kcal - 11,600 = 4 tons = tube size = high - 1/2 low - 3/4


Kcal BTU
6,000 - 24,000 - 2 tons
Lra - 76 Rla - 14.6
Breaker size - 3x the ampere
Capacitor - 34 uf



Fan motor
20 watts - 2 uf
50 watts - 5 uf


18,000 BTU
Capacity - 4,500 ( w )
Running Ampere - 11.6 a
Pipe Length - 20 meter ( 60 feet )



24,000 btu
5,700 w
14.4 ampere
Pipe Length - 20 m (66 ft.)


30,000 btu
6,700 w
17.0 ampere
Pipe Length - 30 meter (98 ft.)

25,000 btu (7.33 kw)
13.7 ampere
Lra 81
Elevation Limit = 30 meter outdoor higher
25 meter outdoor lower

Compressor capacitor = 35 uf
Fan capacitor = 6uf



36,000 btu = 3 ton
Ampere = 16.5 a
Pipe length limit - 40 meter (130 ft.)
Elevation Limit = 40 m Outdoor higher
30 m Outdoor Lower
Fan capacitor = 7.5 uf
Comp. = 35 uf



18,000 btu = 1.5 ton = 2hp
Amp = 10.5
2,180 w
LRA = 58
Rotary(hermetic)
Tube pipe = 1/4 high side, 1/2 low side
Fan Motor = 30 w nominal output - 1.8 uf indoor
Comp = 35 uf



Btu 22,000
6.45 kw
LRA = 76
Tube pipe = 1/4 high, 5/8 low

No comments: